Industrial battery storage facility fire with orange flames, black smoke, and emergency vehicles responding at dusk.

Why do battery storage facilities catch fire?

Battery storage fire incidents occur due to thermal runaway, electrical faults, manufacturing defects, and external factors like physical damage or extreme temperatures. These large-scale systems contain thousands of lithium-ion cells that can rapidly escalate from a single cell failure to facility-wide fires, making proper risk management essential for commercial renewable energy installations.

What causes battery storage facilities to catch fire?

Battery storage facilities catch fire primarily due to thermal runaway in lithium-ion cells, electrical system faults, manufacturing defects, and external damage. The most common trigger is thermal runaway, where individual battery cells overheat and create a chain reaction throughout the system.

Electrical faults represent another significant risk factor. Poor wiring, faulty connections, or damaged power conversion systems can generate heat and sparks that ignite battery components. These electrical issues often stem from inadequate installation practices or component degradation over time.

Manufacturing defects in battery cells create inherent fire risks that may not manifest until months or years after installation. Defective cells can develop internal short circuits, leading to rapid heating and potential fire. External factors such as physical damage from accidents, extreme weather conditions, or inadequate cooling systems can also trigger fire incidents in battery storage facilities.

The scale of commercial battery installations amplifies these risks significantly. Large facilities contain hundreds or thousands of battery modules, meaning a single cell failure can potentially affect the entire system if proper containment measures aren’t in place.

How does thermal runaway lead to battery fires?

Thermal runaway occurs when a lithium-ion battery cell generates heat faster than it can dissipate it, causing temperature and pressure to rise uncontrollably. This process becomes self-sustaining and can spread rapidly from cell to cell throughout large battery installations.

Thermal runaway in lithium-ion batteries occurs when temperatures reach their critical thermal threshold, which varies depending on the battery chemistry often ranging from around 130°C for NMC cells to up to 250°C for LFP cells. This reaction can cause fires that spread rapidly and release toxic gases such as hydrogen fluoride (HF) and carbon monoxide (CO). At this temperature, the electrolyte begins decomposing and releasing flammable gases. As internal pressure builds, the cell temperature continues rising, often exceeding 500°C within minutes.

In large battery storage systems, thermal runaway becomes particularly dangerous due to thermal propagation. Heat from one failing cell can trigger thermal runaway in adjacent cells, creating a cascading effect throughout battery modules. This cell-to-cell propagation can occur within seconds or minutes, depending on the battery chemistry and thermal management system.

Lithium iron phosphate (LFP) batteries are generally more thermally stable than nickel manganese cobalt (NMC) variants, but both chemistries can experience thermal runaway under certain conditions. The rapid temperature rise and gas generation make thermal runaway extremely difficult to control once it begins, which is why prevention through proper battery management systems is crucial.

What are the warning signs before a battery storage fire occurs?

Early warning signs include unusual temperature spikes, abnormal gas emissions, voltage irregularities, and monitoring system alerts. These indicators typically appear hours or days before a fire incident, providing opportunities for preventive action.

Temperature monitoring systems often detect the first signs of potential thermal runaway. Cells experiencing internal faults may show gradual temperature increases above normal operating ranges. Battery management systems should trigger alerts when individual cells exceed predetermined temperature thresholds, typically around 45-50°C for most lithium-ion chemistries.

Gas detection systems can identify the release of electrolyte vapours and other gases that precede thermal runaway. These emissions often have distinctive odours and chemical signatures that specialised sensors can detect before visible smoke appears.

Electrical monitoring reveals voltage imbalances between cells, unexpected current fluctuations, or resistance changes that indicate developing faults. Modern battery management systems continuously monitor these parameters and can identify cells showing signs of degradation or potential failure.

Physical inspection may reveal cell swelling, discolouration, or electrolyte leakage. Regular visual inspections by qualified technicians can identify these warning signs before they progress to fire incidents. Professional inspection services help ensure early detection of potential problems in commercial installations.

How can battery storage fire risks be minimised?

Fire risks are minimised through proper system design, advanced fire suppression systems, regular professional inspections, effective thermal management, and comprehensive safety protocols. A multi-layered approach provides the best protection for large-scale battery storage facilities.

System design plays a crucial role in fire prevention. Proper spacing between battery modules, fire-resistant barriers, and adequate ventilation help prevent fire spread. Battery management systems with robust monitoring and automatic shutdown capabilities can detect problems early and isolate affected sections before fires develop.

Specialised fire suppression systems designed for battery fires are essential. While large volumes of water are often used by emergency services to cool adjacent cells and prevent propagation, traditional water sprinklers may be ineffective at suppressing the core reaction and pose electrical and toxic runoff hazards. Gas-based suppression systems or specialised cooling fluids can more effectively control battery fires and prevent re-ignition.

Regular professional inspections help identify potential problems before they become fire hazards. While Scope 12 inspections are not legally required, many insurers mandate them for commercial solar and battery installations. These comprehensive assessments evaluate electrical systems, thermal management, and safety equipment functionality.

Thermal management systems must maintain battery temperatures within safe operating ranges. Proper cooling and ventilation prevent the temperature buildup that can trigger thermal runaway. Environmental controls should account for both normal operation and emergency cooling requirements.

What happens when a battery storage facility catches fire?

Battery storage fires burn extremely hot, release toxic gases, present unique emergency response challenges, and can impact surrounding areas for extended periods. These incidents require specialised firefighting approaches and extensive safety precautions.

Battery fires typically reach temperatures exceeding 500°C and can burn for hours or even days. The intense heat can damage nearby structures and equipment, while the fire’s persistence makes complete extinguishment difficult. Re-ignition can occur hours after the fire appears controlled, requiring extended monitoring.

Toxic gas emissions pose serious health risks during battery fires. Burning lithium-ion batteries release hydrogen fluoride, carbon monoxide, and other dangerous compounds. These gases can travel significant distances, requiring evacuation of surrounding areas and specialised breathing equipment for emergency responders.

Emergency response teams face unique challenges with battery fires. Standard firefighting techniques may be ineffective or dangerous, and the toxic gas emissions require specialised equipment and training. Water application can create additional hazards through potential electrical shock and toxic runoff.

The impact on surrounding areas can be substantial and long-lasting. Toxic gas clouds may require evacuation of nearby buildings, while contaminated water runoff needs proper containment and disposal. Business interruption and environmental cleanup costs can extend far beyond the initial fire damage, making comprehensive insurance coverage essential for commercial installations.

Understanding these fire risks and prevention strategies is crucial for anyone involved in commercial battery storage projects. Proper risk management, including appropriate insurance coverage and regular professional inspections, helps protect investments and ensure safe operation of these critical energy storage systems.

Protect Your Battery Storage Investment

Don’t leave your battery storage facility vulnerable to fire risks. Implementing proper safety measures, regular inspections, and comprehensive fire prevention strategies is essential for protecting your investment and ensuring operational safety. Our team of experts can help you assess your current fire safety protocols and develop customised solutions for your specific installation. Contact us today to discuss how we can help safeguard your battery storage facility with professional risk assessment and tailored safety solutions.

Insurance and inspection needs for your BESS?

Contact us today if you want to know more about the possibilities in BESS insurance and Scope inspections.

📧 Email: support@solarif.com
☎️ Phone: +31 (0)26 711 5050