BESS all risk insurance can cover thermal runaway, but only when the fire or explosion damage is not excluded and the installation meets the insurer’s conditions. Coverage typically focuses on physical damage to the battery system and related business interruption. Terms vary by insurer, so the exact wording decides what is actually paid. Below, we answer the key questions B2B owners, developers, and financiers ask about thermal runaway coverage.

What does an all risk policy actually pay for after a battery fire?

An all risk policy for battery energy storage generally pays for sudden, unforeseen physical damage to the insured BESS, including damage caused by fire. The insured property is covered unless a specific exclusion applies. That makes the policy wording and its exclusions more important than the headline coverage.

After a thermal runaway incident, the physical damage section typically addresses the repair or replacement of damaged battery modules, racks, containers, inverters, and connected electrical equipment. Costs that often come with a fire, such as clearing debris and securing the site, may be included depending on how the policy is written. Always check which of these cost items are named in the wording and at what limit.

Owners often assume that “all risk” means everything is covered. In practice, it means the policy starts from a broad base and then narrows through exclusions, sub-limits, and conditions. A well-structured energy storage all risks insurance program makes those boundaries clear before a loss happens, not after.

Protect Your Energy Storage Investment

Discuss Your BESS Insurance Requirements

Explore BESS Insurance

Which thermal runaway losses are commonly excluded or limited?

Commonly excluded or limited thermal runaway losses include damage from defects the insurer considers manufacturing or design faults, wear and tear, losses linked to unmet safety conditions, and costs to improve the system beyond its prior state. Sub-limits can also cap certain categories of loss.

Typical exclusion and limitation areas to review in battery storage insurance exclusions include:

  • Defective design, materials, or workmanship: The faulty part itself may not be covered, even if resulting damage is.
  • Gradual deterioration: Capacity loss, ageing, and normal degradation are not sudden physical damage.
  • Non-compliance with insurer conditions: If agreed safety measures were missing or not maintained, the insurer may reduce or decline a claim.
  • Improvements and upgrades: Replacement is usually on a like-for-like basis rather than with a better system.
  • Sub-limits and deductibles: Fire-related losses can carry their own limits and higher deductibles.

Because thermal runaway is a known hazard in lithium-ion storage, insurers pay close attention to it. Read the definitions of fire and explosion, and any battery-specific clauses carefully.

How does business interruption cover work after a BESS incident?

BESS business interruption insurance compensates for lost income and continuing fixed costs while the system is out of service after an insured physical damage event. It does not stand alone. The business interruption claim generally depends on a covered damage claim being accepted first.

The calculation usually looks at what the system would have earned had the incident not occurred, minus costs that stop during the downtime, plus the fixed costs that continue. For a storage asset, revenue may come from arbitrage, grid services, or contracted capacity, so documenting these income streams matters. Clear financial records make a claim easier to calculate and agree on.

Pay attention to the indemnity period. Replacing battery components or waiting for permits and grid reconnection can take time, and a short indemnity period may end before operations resume. Waiting periods, which are the time before cover begins, also affect the outcome. Discuss realistic restoration timelines with your broker when setting these terms.

What do insurers require before covering thermal runaway risk?

Insurers typically require evidence that the BESS has been designed, installed, and operated to limit the chance and spread of thermal runaway. They look at installation location, distances to buildings, fire barriers, detection and suppression, monitoring, and maintenance. Requirements differ by insurer and project.

Common areas of insurer attention include:

  1. Siting and separation: Distance from buildings and other assets, and fire barriers between containers or units.
  2. Detection and suppression: Systems suited to early detection of off-gassing, heat, or smoke, and a defined fire response.
  3. Battery management and monitoring: Continuous oversight of temperature, voltage, and faults.
  4. Physical protection: Measures against impact, intrusion, and environmental exposure.
  5. Maintenance and operating procedures: Documented routines and emergency plans.

As an insurance broker specialising in renewable energy projects, we see that insurers sometimes offer lower premiums for BESS installations with comprehensive thermal runaway prevention systems, or will not insure systems lacking them at all. On the fire response side, water can worsen battery fires because of electrical conductivity and the spreading of electrolytes, but it is currently the most recommended method for cooling and de-escalating the situation, so the response plan should be agreed with the insurer and local fire services.

How can a BESS owner show an installation meets insurer expectations?

A BESS owner can show compliance by preparing clear documentation that covers the design, the safety systems, and the operating routines. A complete submission lets the insurer assess the risk quickly and reduces back and forth, which often improves the terms offered.

Useful evidence to assemble includes:

  • Site layout drawings showing distances, barriers, and access routes for emergency services
  • Technical specifications of the battery system, battery management, and fire detection and suppression
  • Manufacturer and installer information, including relevant certifications and test documentation
  • Commissioning records and a maintenance plan
  • An emergency response plan, ideally aligned with local fire services

Involve your insurance contact early, ideally during design, since changing siting or fire protection after construction is costly. Presenting a structured risk file shows the insurer that thermal runaway risk is managed rather than assumed away.

Should BESS owners rely on a specialist broker for this cover?

Yes, for commercial and utility-scale projects a specialist broker is usually the better route. Thermal runaway cover depends on technical requirements, exclusions, and policy wording that general advisers may not handle in depth. A broker with a renewable energy focus can match the project to insurers that understand storage risk.

Evaluate a broker on these criteria:

  • Demonstrable experience with battery storage and solar projects
  • Access to insurers willing to cover BESS fire and thermal runaway risk
  • Ability to explain exclusions and business interruption terms in plain language
  • Support in presenting the installation to insurers in the way they expect

Keep in mind that a broker advises on and arranges cover, while the insurer is the party that carries the risk. Choosing a broker is about advice, market access, and negotiation, not about who provides the policy itself.

How Solarif helps with thermal runaway coverage

We are an insurance broker, not an insurer, with an exclusive focus on solar and renewable projects. Since 2009, we have insured 3.8 GW of capacity and carried out 521 Scope 12 inspections. We use this experience to help B2B clients arrange BESS insurance that fits their risk profile.

  • Tailored all risk cover: We arrange energy storage all risks insurance covering property damage and business interruption, structured around your installation.
  • Clarity on exclusions: We explain what is covered, limited, or excluded so there are no surprises after an incident.
  • Insurer requirement guidance: We help you understand what insurers expect on siting, fire protection, and safety measures before you build or operate.
  • Access to A-rated insurers: Our international network gives us access to insurers and certified partners.
  • Integrated risk support: We combine insurance with risk management and inspection expertise for a complete approach.

Ready to secure thermal runaway coverage for your battery storage project? Contact our experts and request a quote today.

Frequently Asked Questions

How do I get started with arranging thermal runaway coverage for a new BESS project?

Start during the design phase rather than after construction. Share your site layout, battery and fire protection specifications, and installer details with a specialist broker so they can identify insurer requirements early. This gives you time to adjust siting, separation distances, or suppression systems before they become costly to change, and it usually leads to better terms.

What happens if my BESS fire protection or monitoring system is not working at the time of a loss?

If agreed safety measures were missing, switched off, or poorly maintained, the insurer may reduce or decline the claim, depending on how the conditions are worded. To avoid this, keep maintenance logs, test records, and alarm histories up to date, and notify your broker promptly if a safety system is temporarily out of service so you can agree on interim measures.

Will my insurer pay to replace a damaged battery with a newer or higher-capacity model?

Usually not. Replacement is typically on a like-for-like basis, so upgrades or improvements beyond the prior condition are generally excluded or must be paid by the owner. If the original model is no longer available, discuss with your broker in advance how the policy handles replacement with an equivalent specification.

What should I do immediately after a thermal runaway incident to protect my claim?

First prioritise safety and follow your emergency response plan with local fire services. Then notify your broker and insurer as soon as possible, document the scene with photos and system data before anything is removed, and take reasonable steps to limit further damage. Keep all records of costs and downtime, as they support both the property damage and business interruption claims.

How can I make sure my business interruption indemnity period is long enough?

Map out a realistic restoration timeline that includes ordering replacement battery modules, installation, testing, permits, and grid reconnection, not just the repair itself. Lead times for specialised components can be long, so discuss these with your broker and manufacturer when setting the indemnity period. Also review the waiting period so that the cover starts when you need it.

Can a thermal runaway claim be rejected because of a manufacturing defect in the battery?

The defective part itself is often excluded, but resulting damage to other property may still be covered depending on the wording. Check how the policy defines defective design, materials, and workmanship, and whether there are any battery-specific clauses. Manufacturer warranties and performance guarantees can complement the policy for the defect portion of a loss.

Do insurers offer better terms if I add extra fire safety measures?

Often yes. Insurers may offer lower premiums or broader terms for installations with comprehensive thermal runaway prevention, early detection, and strong separation and monitoring, while some will not insure systems without them. Presenting a well-documented risk file that shows these measures can strengthen your position when negotiating terms.