What is thermal runaway?

Thermal runaway is a dangerous chain reaction where lithium-ion battery cells overheat uncontrollably, potentially leading to fire, explosion, and toxic gas emissions. This phenomenon occurs when one cell’s temperature rises beyond safe limits, causing adjacent cells to overheat in succession throughout the battery system. For solar projects and renewable energy installations, thermal runaway poses serious safety risks and can result in catastrophic financial losses.

bess

What exactly is Thermal runaway and why should you be concerned?

Thermal runaway is an uncontrolled exothermic reaction in lithium-ion battery cells where heat generation exceeds heat dissipation, creating a self-sustaining cycle of increasing temperatures. Once initiated, the process spreads from cell to cell within the battery module, potentially affecting entire battery packs or containers.

The chain reaction begins when a single cell reaches temperatures above its thermal stability threshold, typically around 130-150°C for most lithium-ion chemistries. At these temperatures, the battery’s internal chemical reactions become unstable, generating additional heat and potentially flammable gasses. This heat then affects neighboring cells, causing them to reach their thermal runaway temperature and perpetuating the dangerous cycle.

For renewable energy project stakeholders, thermal runaway represents one of the most serious risks in battery energy storage systems. The financial implications extend beyond equipment replacement costs to include business interruption, insurance claims, regulatory investigations, and potential liability issues. Projects can face extended downtime whilst safety investigations are conducted and systems are rebuilt to meet enhanced safety standards.

The concern is particularly acute given that lithium-ion batteries, especially those using NMC (Nickel Mangan Kobalt) chemistry, are susceptible to thermal runaway under certain conditions. Even LFP (Lithium Iron Phosphate) batteries, whilst more thermally stable, are not entirely immune to this phenomenon when subjected to extreme conditions or manufacturing defects.

What causes thermal runaway in battery energy storage systems?

Several primary triggers can initiate thermal runaway in BESS installations, with overcharging being one of the most common causes. When batteries receive more energy than they can safely store, excess energy converts to heat, potentially pushing cell temperatures beyond safe operating limits.

Physical damage to battery cells, whether from impact during installation, vibration, or manufacturing handling issues, can compromise internal separators and create internal short circuits. These shorts generate localized heating that can rapidly escalate to thermal runaway conditions.

Manufacturing defects present another significant risk factor. Issues such as contaminated electrode materials, improper separator thickness, or inadequate quality control during cell assembly can create weak points that fail under normal operating conditions. Even microscopic metal particles introduced during manufacturing can eventually pierce internal separators and trigger thermal events.

Extreme temperatures, both high and low, stress battery chemistry and can initiate thermal runaway. High ambient temperatures reduce the thermal margin available before runaway conditions occur, whilst very low temperatures can cause lithium plating during charging, creating internal shorts when the battery warms up.

Electrical faults within the Battery Management System (BMS) or Power Conversion System (PCS) can also trigger thermal runaway. Voltage imbalances between cells, failed cooling systems, or malfunctioning charge controllers can create conditions where individual cells become stressed beyond their safe operating parameters.

How dangerous is a Thermal runaway event?

A Thermal runaway event poses extreme dangers including intense fires reaching temperatures above 1000°C, toxic gas emissions, and potential explosions. The consequences can be catastrophic for both personnel safety and business operations, making thermal runaway one of the most feared incidents in energy storage.

Fire hazards represent the most immediate danger. Thermal runaway fires burn extremely hot and are notoriously difficult to extinguish using conventional firefighting methods. Water can actually worsen the situation by conducting electricity and potentially spreading burning electrolyte. These fires can persist for hours or even days, requiring specialized suppression systems and trained emergency responders.

Toxic gas emissions create serious health risks for anyone in the vicinity. During thermal runaway, batteries release hydrogen fluoride, carbon monoxide, and other poisonous gasses that can cause respiratory damage, chemical burns, and in severe cases, fatalities. These gasses can travel significant distances from the source, potentially affecting neighboring properties and communities.

Explosion risks arise from the rapid generation of gasses within sealed battery enclosures. If these gasses cannot vent safely, pressure buildup can cause violent explosions that propel battery components and toxic materials over wide areas. Container-based BESS installations are particularly vulnerable to this type of catastrophic failure.

Property damage extends far beyond the immediate battery system. Thermal runaway events can destroy entire facilities, damage surrounding infrastructure, and contaminate soil and groundwater with toxic materials. The cleanup costs alone can exceed the original project value, whilst environmental remediation may take years to complete.

Business interruption impacts are equally severe. Projects may face months or years of downtime whilst investigations are conducted, insurance claims are processed, and replacement systems are designed with enhanced safety measures. Revenue losses during this period, combined with increased insurance premiums and potential regulatory penalties, can make projects financially unviable.

What are the warning signs of potential thermal runaway in BESS?

Early warning signs of potential thermal runaway include unusual heating patterns, visible swelling of battery modules, smoke emission, and distinctive chemical odors. Monitoring these indicators allows operators to take preventive action before conditions escalate to dangerous levels.

Temperature anomalies are often the first detectable sign of impending thermal runaway. Individual cells or modules showing temperatures significantly higher than their neighbors, or gradual temperature increases without corresponding load increases, indicate potential internal problems. Modern thermal monitoring systems can detect temperature variations as small as a few degrees Celsius.

Physical changes to battery modules provide visual warning signs. Swelling or bulging of battery cases indicates internal gas generation, whilst any visible deformation suggests internal pressure buildup that could precede thermal runaway. Discoloration of battery housings or surrounding materials may indicate previous overheating episodes.

Smoke emission, even in small quantities, represents a serious warning sign requiring immediate attention. The smoke may appear white or grey initially and often carries a distinctive chemical smell. Any visible vapor or haze around battery installations should trigger emergency shutdown procedures.

Strange odors, particularly sweet, metallic, or acrid smells, can indicate electrolyte leakage or internal chemical reactions. These odors may be detectable before visual signs appear and should never be ignored during routine inspections.

Voltage irregularities and monitoring system alerts provide electronic early warning capabilities. Cells showing voltage imbalances, unexpected capacity losses, or increased internal resistance may be developing internal faults that could lead to thermal runaway. Advanced BMS systems can detect these electrical anomalies and provide automated alerts to operators.

How can you prevent thermal runaway in battery storage systems?

Preventing thermal runaway requires comprehensive strategies including proper system design, quality component selection, effective thermal management, regular inspections, and robust safety protocols. A multi-layered approach significantly reduces the risk of thermal runaway incidents in BESS installations.

Proper system design forms the foundation of thermal runaway prevention. This includes selecting appropriate battery chemistries for the application, with LFP batteries offering superior thermal stability compared to NMC alternatives. Adequate spacing between battery modules allows heat dissipation and prevents thermal propagation between units.

Quality component selection cannot be overstated in importance. Choosing batteries from reputable manufacturers with proven track records, comprehensive testing protocols, and appropriate certifications reduces the risk of manufacturing defects. Similarly, selecting high-quality BMS and PCS components ensures proper monitoring and control of battery operations.

Thermal management systems must be designed to handle both normal operating conditions and potential fault scenarios. This includes active cooling systems, proper ventilation, and thermal barriers between battery modules. Emergency cooling systems should activate automatically when temperatures exceed predetermined thresholds.

Regular inspections and maintenance programs help identify potential problems before they escalate. These should include thermal imaging surveys, electrical testing, physical inspections for signs of damage or deterioration, and verification of safety system functionality. Professional inspection services can identify subtle changes that might escape routine monitoring.

Monitoring systems provide continuous oversight of battery conditions. Advanced BMS installations should monitor individual cell voltages, temperatures, and internal resistance whilst providing automated responses to abnormal conditions. Integration with facility management systems allows rapid response to potential thermal runaway situations.

Safety protocols must include emergency response procedures, personnel training, and coordination with local fire services. Staff should understand the unique hazards associated with lithium-ion battery fires and know how to safely evacuate areas and summon appropriate emergency response. Regular drills ensure these procedures remain effective when needed most.

Understanding and managing Thermal runaway risks is essential for the safe operation of renewable energy projects. With proper prevention strategies, monitoring systems, and emergency procedures, these risks can be effectively managed whilst maintaining the operational benefits that battery storage brings to solar and renewable energy installations.

Insurance and inspection needs for your BESS?

Contact us today if you want to know more about the possibilities in BESS insurance and Scope inspections.

📧 Email: support@solarif.com
☎️ Phone: +31 (0)26 711 5050